RollSeal RS-500 Manuel de service Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 34
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
4801-5159 Rev 01-2015 Technical Installation and Service Manual Page 11
5 Controller Installation and Setup
5.1 Tools Required
Small Screwdriver Standard Screwdriver Wire Strippers
5.2 Installation Instructions
1. Unpack system, and check that all components are present.
1 RollSeal Smart Controller
1 Installation Kit
1 Manual
2. Hang the controller with four screws at the desired location.
3. Make sure all power supplies are disconnected before breaking any wires, or reaching into the
controller enclosure.
4. Determine the required Powering Voltage whether 115 VAC (SC-325 only) or 230 VAC.
5. If the desired power supply voltage is different from the factory preset/prewired voltage, the
appropriate version Brake Rectifier must be ordered separately, field-installed on the RS Door, and
the SC controller switch & jumper settings changed accordingly. The SC-325 Controllers are factory
preset to 115 VAC and the RS-500 Doors factory prewired to require a 115 VAC power supply. The
SC-650 Controllers are factory preset to 230 VAC and the RS-600 Doors factory prewired to require
a 230 VAC power supply. The SC-325 Controller can be field upgraded to accommodate either 115
VAC or 230 VAC power supply. Refer to Section 6 for the SC Controller power wiring, switch
setting, and jumper setting and Section 15 for the Motor Brake Rectifier part numbers and wiring
information.
Warning!
Only Qualified Electrical Personnel Familiar With The Construction And Operation Of This
Equipment And The Hazards Involved Should Install, Adjust, And/Or Service This Equipment.
Read And Understand This Manual In Its Entirety Before Proceeding.
Failure To Observe This Precaution Could Result In Severe Bodily Injury Or Death!
Warning!
Dangerous High Voltages!
Allow Approximately 5 Minutes For The Controller To Power-Down Before Changing Switch
Setting, Jumper Placement, Or Wiring.
6. Connect power. See Section 6.
7. Connect AC/DC Harness hook up.
8. Turn the controller on.
9. Set the Open and Closed Speed and Limits, the Acceleration and Deceleration Ranges, Close Time
Delay and Switch positions. See Section 8 and Manual No 4801-5156 for more information.
!
!