RollSeal RS-500 Spécifications Page 26

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 50
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 25
Page 26 RollSeal SC-325 & SC-650 Controllers Part No 4801-5156 Rev 10-2014
Control
Outside
Switch
Inside
Switch
CPC
Conduit
Straps
CPC
Covers
Drill a minimum of
1” hole.
Cooler
Wall
10.4 Connection of Controller to Head Unit.
1. Mount controller at desired location within 3’ of junction box on
Head Unit.
2. Controller has and AC and DC harness prewired that connects to
head unit as shown in Diagram.
10.5 Installing Prewired Switches
Cooler Switches are prewired with a CPC quick connect. You have two switch assemblies an Outside Cooler
with harness out the top that is 6’ long and an Inside Cooler with harness out the bottom that is 1.5’ long.
1. Connect Outside switch to Controller
with CPC connection. Push and turn
CPC connector until it’s completely
locked in place.
2. Mount Outside Switch in
desired location on cooler
wall. Note: Cover removed
for mounting.
3. Drill 1” hole through Cooler
Wall to run Inside Switch out
to connect to Outside Switch.
4. Route Inside Switch Harness
through hole and connect to
bottom of Outside Switch
with CPC.
5. Mount Inside Switch in desired
location. Note: Cover removed
for mounting.
6. Install Conduit Straps on conduit
as required. Mount a strap close to
CPC connection to prevent
tampering.
Insure conduit is run in a way to
prevent moisture from running
into electrical units.
7. Seal hole
DC Plug
AC Plug
Vue de la page 25