Part No 4801-5154 Rev 01-2015 RS-500/600 Series Doors Page 27
16 Installation of RS-500/600 Series Doors (Freezer Kit Included)
Installation of a RS-500/600 series Automatic Freezer Door involves connecting to the Smart Controller SC-325 and
SC-650 that connects to the AC power, the door motor, the Up/Down button, and the safety beam, plus connecting
the Condensation Management System (CMS) Unit and associated duct work. Other accessories can be added such
as a remote IR sensor, a remote radio link, and door movement indicators such as lights and bells.
16.1 Tools Required
3/8 in. (10 mm) Power screwdriver (portable)
3/16 in. (5 mm) Drill bit and power drill
3/8 x 1 in. Bolts and nuts (supplied)
Socket
Hammer
Tape measure
Carpenter's level
NOTE: Other Tools May Be Required According To Installation.
16.2 Overview
The RS-500/600 Freezer Door is shipped with pre-assembled vertical members (left track and right tracks),
with floating magnets, and a pre-assembled horizontal member (head unit). Identify components by the
Parts/Assemblies section in back of this manual. When components are received, check for damaged, loose or
missing parts. If there are damaged or missing parts contact your RollSeal distributor immediately. Please
read and understand all instructions in this manual before beginning installation. After the door has been
assembled and attached to the door framing per instructions in Section 13, Page 18 of this manual it is
necessary to install the Condensation Management System (CMS) and ducts to complete the freezer door
installation.